<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Vigitek</title>
	<atom:link href="http://vigitek.biz/feed/" rel="self" type="application/rss+xml" />
	<link>http://vigitek.biz</link>
	<description>Medical Laser Consultants</description>
	<lastBuildDate>Thu, 09 Feb 2012 15:09:14 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
<xhtml:meta xmlns:xhtml="http://www.w3.org/1999/xhtml" name="robots" content="noindex" />
		<item>
		<title>Pulsed Laser Diode Driver LDMPS-6-9</title>
		<link>http://vigitek.biz/pulsed-laser-diode-drivers/pulsed-diode-driver/</link>
		<comments>http://vigitek.biz/pulsed-laser-diode-drivers/pulsed-diode-driver/#comments</comments>
		<pubDate>Mon, 19 Dec 2011 03:01:19 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Pulsed Laser Diode Drivers]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=1217</guid>
		<description><![CDATA[The Power Supply provides pulsed performance of the Laser Diode Modules (1÷9 standard arrays)       Data Sheet: LDMPS-6-9_engl]]></description>
			<content:encoded><![CDATA[<p>The Power Supply provides pulsed performance of the Laser Diode Modules (1÷9 standard arrays)</p>
<p><a href="http://vigitek.biz/wp-content/uploads/2011/12/LDMPS-6-9.jpg"><img class="alignleft size-thumbnail wp-image-1229" title="LDMPS-6-9" src="http://vigitek.biz/wp-content/uploads/2011/12/LDMPS-6-9-150x150.jpg" alt="" width="150" height="150" /></a><br /><a href="http://vigitek.biz/wp-content/uploads/2011/12/LDMPS-6-9.jpg"><br /></a>      <strong>Data Sheet:</strong> <a href="http://vigitek.biz/wp-content/uploads/2011/12/LDMPS-6-9_engl.pdf">LDMPS-6-9_engl</a></p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/pulsed-laser-diode-drivers/pulsed-diode-driver/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mul-T-Lase</title>
		<link>http://vigitek.biz/mul-t-lase-system/mul-t-lase/</link>
		<comments>http://vigitek.biz/mul-t-lase-system/mul-t-lase/#comments</comments>
		<pubDate>Sun, 23 Oct 2011 04:42:22 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Mul-T-Lase System]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=968</guid>
		<description><![CDATA[&#160; Mul-T-Lase is a multifunctional medical laser system designed for the aesthetic dermatology and plastic surgery. Mul-T-Lase presents an entire spectrum of advantages and unique options: Base Platform + Removable Laser Handpiece concept Universal Use. Several laser handpieces have been developed &#8230; <a href="http://vigitek.biz/mul-t-lase-system/mul-t-lase/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top">
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="100%">
<p><img class="alignnone size-large wp-image-1160" title="IMG_3630" src="http://vigitek.biz/wp-content/uploads/2011/10/IMG_3630-768x1024.jpg" alt="" width="640" height="853" /></p>
<p>Mul-T-Lase is a multifunctional medical laser system designed for the aesthetic dermatology and plastic surgery. Mul-T-Lase presents an entire spectrum of advantages and unique options:</p>
<p><strong>Base Platform + Removable Laser Handpiece concept</strong></p>
<ul>
<li><strong><span style="color: #ff0000;">Universal Use. </span></strong>Several laser handpieces have been developed to cover various dermatological issues.   Mul-T-Lase will help you to choose the correct applicator for your treatment. This will insure a complete absorption of a given wavelength by the skin chromophores. and the correct penetration of laser emission into the tissue</li>
<li><strong><span style="color: #ff0000;">Economy.</span></strong> Save space and reduce your cost costs by purchasing only the handpieces for the clinical applications that are really relevant to you.</li>
<li><strong><span style="color: #ff0000;">Upgradeability.</span></strong> Upgrade your system any time in the future when needed</li>
<li><strong><span style="color: #ff0000;">Speed.</span></strong> There are two connective sockets for laser handpiece connections at Mul-T-Lase. Switching between left and right handpieces is virtually instantaneous.</li>
</ul>
<p><strong>User-friendly interface</strong></p>
<ul>
<li>Full color 12&#8221; TFT monitor</li>
<li>A user-friendly interface with a touch-sensitive control</li>
<li>An special card reader protects against unauthorized access and operation of the device</li>
<li>Programmable access levels</li>
<li>Automatic collection of statistical data</li>
</ul>
<p><strong>Design and usability</strong></p>
<ul>
<li>Attractive , aesthetically pleasing design</li>
<li>Mul-T-Lase can be moved and transported easily due to its compact size</li>
<li>Packaging density of the handpieces is one of the highest medical laser industry has ever produced. Our handpieces deliver the highest level of performance for a given dimensions and weight (&lt;1.5 lbs.)</li>
</ul>
</td>
</tr>
<tr>
<td width="100%"> </td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td valign="top">
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p><strong><span style="text-decoration: underline; color: #ff6600;">Handpieces</span></strong></p>
</td>
</tr>
<tr>
<td>
<p>6 laser handpieces are available at the moment:</p>
<ul>
<li><strong><span style="color: #ff0000;">H755</span></strong> - Dual-mode Alexandrite handpiece suitable both for free-running (µsec ort msec range, pigmented lesions) and Q-switched operations.</li>
<li><strong><span style="color: #ff0000;">H755</span></strong> - Alexandrite handpiece for high-energy long pulse operations only (msec range, hair removal).</li>
<li><strong><span style="color: #ff00ff;">H1064</span></strong> - Nd:YAP laser handpiece suitable both for free-running and Q-switched operations; includes <strong><span style="color: #00ff00;">KTP</span></strong> containing tip for 532 nm.</li>
<li><strong><span style="color: #ff00ff;">L1064</span></strong> - Nd:YAG handpiece designed for long pulse operation only (hair removal, leg veins).</li>
<li><strong><span style="color: #0000ff;">F1540 </span></strong>– Er:Glass Fractional Laser Handpiece for non-ablative collagen remodeling</li>
<li><span style="text-decoration: underline;"><strong>L2940/F2940</strong> - erbium handpiece both for ablative and non-ablative skin resurfacing.</span></li>
</ul>
<h1><span style="text-decoration: underline;"><span style="color: #ff0000; text-decoration: underline;"><a href="http://vigitek.biz/wp-content/uploads/2011/10/micro-en5.pdf"><span style="color: #ff0000; text-decoration: underline;">Hand-held Laser Handpieces</span></a></span></span></h1>
<p>The main technical characteristics of laser handpieces are as follows:</p>
</td>
</tr>
<tr>
<td>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="40%"> </td>
<td>
<p><strong><span style="color: #ff0000;">H755</span></strong></p>
</td>
<td>
<p><strong><span style="color: #ff0000;">L755</span></strong></p>
</td>
<td>
<p><strong><span style="color: #ff00ff;">H1064</span></strong></p>
</td>
</tr>
<tr>
<td>
<p>Laser active medium</p>
</td>
<td>
<p>Alexandrite</p>
</td>
<td>
<p>Alexandrite</p>
</td>
<td>
<p>Nd:YAG</p>
</td>
</tr>
<tr>
<td>
<p>Wavelength, nm</p>
</td>
<td>
<p>755</p>
</td>
<td>
<p>755</p>
</td>
<td>
<p>1064</p>
</td>
</tr>
<tr>
<td>
<p>Lasing mode</p>
</td>
<td>
<p>Long pulse,<br />Pulse train,<br />Hybrid</p>
</td>
<td>
<p>Long pulse</p>
</td>
<td>
<p>Long pulse, <br />Pulse train, <br />Hybrid</p>
</td>
</tr>
<tr>
<td>
<p>Pulse width, ms</p>
</td>
<td>
<p>0.1 &#8211; 3</p>
</td>
<td>
<p>1 – 5</p>
</td>
<td>
<p>0.2 &#8211; 20</p>
</td>
</tr>
<tr>
<td>
<p>Energy density, J/cm2</p>
</td>
<td>
<p>1 &#8211; 140</p>
</td>
<td>
<p>1 &#8211; 210</p>
</td>
<td>
<p>1 &#8211; 210</p>
</td>
</tr>
<tr>
<td>
<p>Max. output energy, J</p>
</td>
<td>
<p>   0.5</p>
</td>
<td>
<p>   25</p>
</td>
<td>
<p>0.6 (1064) + 0.4 (532 nm)</p>
</td>
</tr>
<tr>
<td>
<p>Max. repetition rate (@ max. output energy), Hz</p>
</td>
<td>
<p>1</p>
</td>
<td>
<p>1</p>
</td>
<td>
<p>1</p>
</td>
</tr>
<tr>
<td>
<p>Spot Sizes available, dia (mm)</p>
</td>
<td>
<p>1, 3, 6</p>
</td>
<td>
<p>3, 6, 9</p>
</td>
<td>
<p>1, 3, 6</p>
</td>
</tr>
<tr>
<td>
<p>KTP-tip spot sizes, dia (mm)</p>
</td>
<td>
<p>-</p>
</td>
<td>
<p>-</p>
</td>
<td>
<p>1, 3</p>
</td>
</tr>
<tr>
<td> </td>
<td> </td>
<td> </td>
<td> </td>
</tr>
<tr>
<td width="40%"> </td>
<td>
<p><strong><span style="color: #ff00ff;">L1064</span></strong></p>
</td>
<td>
<p><strong><span style="color: #0000ff;">F1540</span></strong></p>
</td>
<td>
<p><strong>L2940</strong><br /><strong>F2940</strong></p>
</td>
</tr>
<tr>
<td>
<p>Laser active medium</p>
</td>
<td>
<p>Nd:YAG</p>
</td>
<td>
<p>Er:Glass</p>
</td>
<td>
<p>Er:YAG</p>
</td>
</tr>
<tr>
<td>
<p>Wavelength, nm</p>
</td>
<td>
<p>1064</p>
</td>
<td>
<p>1540</p>
</td>
<td>
<p>2940</p>
</td>
</tr>
<tr>
<td>
<p>Lasing mode</p>
</td>
<td>
<p>Long pulse</p>
</td>
<td>
<p>Long pulse</p>
</td>
<td>
<p>Long pulse</p>
</td>
</tr>
<tr>
<td>
<p>Pulse width, ms</p>
</td>
<td>
<p>1 &#8211; 30</p>
</td>
<td>
<p>1 – 5</p>
</td>
<td>
<p>0.2 &#8211; 5</p>
</td>
</tr>
<tr>
<td>
<p>Energy density, J/cm2</p>
</td>
<td>
<p>1 &#8211; 280</p>
</td>
<td>
<p>1 – 35</p>
</td>
<td>
<p>1 &#8211; 280</p>
</td>
</tr>
<tr>
<td>
<p>Max. output energy, J</p>
</td>
<td>
<p>30</p>
</td>
<td>
<p>10</p>
</td>
<td>
<p>2.5</p>
</td>
</tr>
<tr>
<td>
<p>Max. repetition rate (@ max. output energy), Hz</p>
</td>
<td>
<p>1</p>
</td>
<td>
<p>2</p>
</td>
<td>
<p>1</p>
</td>
</tr>
<tr>
<td>
<p>Nozzles available, dia (mm)</p>
</td>
<td>
<p>1, 3, 6, 9</p>
</td>
<td>
<p>6, 9</p>
</td>
<td>
<p>1, 3, 6</p>
</td>
</tr>
<tr>
<td>
<p>Fractional nozzles available, <br />dia (mm) x microspots/cm2</p>
</td>
<td>
<p>-</p>
</td>
<td>
<p>9 x 100<br />6 x 400</p>
</td>
<td>
<p>9 x 100<br />6 x 400</p>
</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td> </td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td valign="top">
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p><span style="text-decoration: underline;"><strong><span style="color: #ff6600; text-decoration: underline;">Skin Conditions</span></strong></span></p>
</td>
</tr>
<tr>
<td>
<p>At least 9 pathologies can be effectively treated with LASEST handpieces. A summary table is given below.</p>
</td>
</tr>
<tr>
<td>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%"> </td>
<td>
<p><strong><span style="color: #ff0000;">H755</span></strong></p>
</td>
<td>
<p><strong><span style="color: #ff0000;">L755</span></strong></p>
</td>
<td>
<p><strong><span style="color: #ff00ff;">H1064</span></strong><br /><strong>&amp; <span style="color: #00ff00;">KTP</span></strong></p>
</td>
<td>
<p><strong><span style="color: #ff00ff;">L1064</span></strong></p>
</td>
<td>
<p><strong><span style="color: #0000ff;">F1540</span></strong></p>
</td>
<td>
<p><strong>L2940</strong><br /><strong>F2940</strong></p>
</td>
</tr>
<tr>
<td>
<p>Hair removal (reduction)</p>
</td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
</tr>
<tr>
<td>
<p>Vascular lesions</p>
</td>
<td> </td>
<td> </td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
</tr>
<tr>
<td>
<p>Pigmented lesions</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
<td> </td>
</tr>
<tr>
<td>
<p>Tattoo removal</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
<td>
<p>+ / +</p>
</td>
</tr>
<tr>
<td>
<p>Laser rejuvenation</p>
</td>
<td> </td>
<td> </td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
<td>
<p>+ / +</p>
</td>
</tr>
<tr>
<td>
<p>Acne</p>
</td>
<td> </td>
<td> </td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td> </td>
</tr>
<tr>
<td>
<p>Fractional thermolysis</p>
</td>
<td> </td>
<td> </td>
<td> </td>
<td> </td>
<td>
<p>+</p>
</td>
<td>
<p>- / +</p>
</td>
</tr>
<tr>
<td>
<p>Stretch marks</p>
</td>
<td> </td>
<td> </td>
<td> </td>
<td> </td>
<td>
<p>+</p>
</td>
<td>
<p>- / +</p>
</td>
</tr>
<tr>
<td>
<p>Scars</p>
</td>
<td>
<p>+</p>
</td>
<td> </td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td>
<p>+</p>
</td>
<td>
<p>+ / +</p>
</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td> </td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td valign="top">
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p><span style="text-decoration: underline;"><strong><span style="color: #ff6600; text-decoration: underline;">Specifications</span></strong></span></p>
</td>
</tr>
<tr>
<td>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p><strong>Medical standards compliance:</strong></p>
</td>
<td>
<p>IEC 60601-1;             60601-1-2      ;            60601-1-4      ; 60664-1; 60825-1; 61000-3-2; CISPR 11</p>
</td>
</tr>
<tr>
<td>
<p><strong>Base unit:</strong></p>
</td>
<td> </td>
</tr>
<tr>
<td>
<p>Voltage</p>
</td>
<td>
<p>230 VAC, 50/60 Hz</p>
</td>
</tr>
<tr>
<td>
<p>Power consumption</p>
</td>
<td>
<p>2.3 kW</p>
</td>
</tr>
<tr>
<td>
<p>Dimensions</p>
</td>
<td>
<p>45*45*75 cm</p>
</td>
</tr>
<tr>
<td>
<p>Weight</p>
</td>
<td>
<p>53 kg</p>
</td>
</tr>
<tr>
<td>
<p><strong>Laser handpieces:</strong></p>
</td>
<td> </td>
</tr>
<tr>
<td>
<p>Dimensions</p>
</td>
<td>
<p>25*5*3.5 cm</p>
</td>
</tr>
<tr>
<td>
<p>Weight</p>
</td>
<td>
<p>0.5 kg</p>
</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td> </td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<table style="width: 100%;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p><strong><span style="text-decoration: underline; color: #ff6600;">Gallery</span></strong></p>
</td>
</tr>
<tr>
<td>
<table style="width: 100%;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top"><img class="alignleft size-large wp-image-1048" title="IMG_3634" src="http://vigitek.biz/wp-content/uploads/2011/10/IMG_3634-686x1024.jpg" alt="" width="640" height="955" /></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/mul-t-lase-system/mul-t-lase/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TEC-series temperature controllers</title>
		<link>http://vigitek.biz/tec-controllers/tec-series-temperature-controllers-2/</link>
		<comments>http://vigitek.biz/tec-controllers/tec-series-temperature-controllers-2/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 23:25:13 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[TEC controllers]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=919</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/tec-controllers/tec-series-temperature-controllers-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TEC-series temperature controllers</title>
		<link>http://vigitek.biz/uncategorized/tec-series-temperature-controllers/</link>
		<comments>http://vigitek.biz/uncategorized/tec-series-temperature-controllers/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 16:45:32 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=885</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/uncategorized/tec-series-temperature-controllers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LNF-series flashlamp pumped OEM laser heads</title>
		<link>http://vigitek.biz/oem-laser-heads/lnf-series-flashlamp-pumped-oem-laser-heads/</link>
		<comments>http://vigitek.biz/oem-laser-heads/lnf-series-flashlamp-pumped-oem-laser-heads/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 16:41:01 +0000</pubDate>
		<dc:creator>alex</dc:creator>
				<category><![CDATA[OEM Laser Heads]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=447</guid>
		<description><![CDATA[Description LNF series flashlamp-pumped pulse OEM laser heads operate in free-running mode with wavelengths 755, 1064, 1320, 1440, 1540, 2108 and 2940 nm and are designed for using in medical and industrial laser systems. Laser rods and flashlamps from the &#8230; <a href="http://vigitek.biz/oem-laser-heads/lnf-series-flashlamp-pumped-oem-laser-heads/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<h2>Description</h2>
<p>LNF series flashlamp-pumped pulse OEM laser heads operate in free-running mode with wavelengths 755, 1064, 1320, 1440, 1540, 2108 and 2940 nm and are designed for using in medical and industrial laser systems.</p>
<p>Laser rods and flashlamps from the best manufacturers provide high efficiency and reliability. The use of stainless-steel pump chambers with glazed ceramic reflectors provides high efficiency and reliability. Laser heads are designed with the attention to cavity stability. Special design of mirror holders with adjustment screws blocking and base plate made from non-tensioned aluminium increase the mechanical and temperature stability of laser heads.</p>
<h2>Specifications</h2>
<h2><span style="font-size: small;"><img class="alignnone size-full wp-image-909" title="Untitled" src="http://vigitek.biz/wp-content/uploads/2011/10/Untitled.jpg" alt="" width="640" height="583" /><br /></span></h2>
<h2>Options</h2>
<p>LNF-series laser heads may be equipped with:</p>
<ul>
<li>metallic coverage case;</li>
<li>pilot laser;</li>
<li>fiber coupling unit;</li>
<li>fiber handpieces of different types</li>
</ul>
<p>Alexandrite laser head LNF-755 may be supplied <a title="Contact us" href="http://vigitek.biz/contact-us/">on request</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/oem-laser-heads/lnf-series-flashlamp-pumped-oem-laser-heads/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>QBD-BT-series bench-top Pockels cell drivers</title>
		<link>http://vigitek.biz/high-voltage-switches/qbd-bt-series-bench-top-pockels-cell-drivers-2/</link>
		<comments>http://vigitek.biz/high-voltage-switches/qbd-bt-series-bench-top-pockels-cell-drivers-2/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 05:43:36 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Pockels Cell Drivers & HV Switches]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=831</guid>
		<description><![CDATA[Description QBD-BT-series consist of ten Pockels cell drivers differ with their output voltage range (up to 6.0 kV) and operating scheme (see also How to order? section). Operating scheme may be either (pull down scheme (= normally on) or push &#8230; <a href="http://vigitek.biz/high-voltage-switches/qbd-bt-series-bench-top-pockels-cell-drivers-2/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<h2>Description</h2>
<p>QBD-BT-series consist of ten Pockels cell drivers differ with their output voltage range (up to 6.0 kV) and operating scheme (see also How to order? section).</p>
<p>Operating scheme may be either (pull down scheme (= normally on) or push up scheme (= normally off). Scheme should be predefined at the time of order.<br /><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbd-bt-t1.jpg" alt="" /><br />High repetition rates and fast transition times are additional benefits of QBD-BT-series Pockels cell drivers.</p>
<h2>Performance</h2>
<p>For 5.0 kV modification continuously operated in internal synchronization mode we warrant the performance table as follows:<br /><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbd-bt-t2.jpg" alt="" /></p>
<p>External synchronization mode shows usually a little higher performance.</p>
<p>In the burst-mode (= short time operations) performance is increasing approximately twice and may achieve 100 kHz value at low operating voltages and load capacitance.</p>
<p>High load capacitance decreases the performance.</p>
<h2>Specification</h2>
<p><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbd-bt-t3.jpg" alt="" /></p>
<h2>How to order?</h2>
<p><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbd-bt-t4.jpg" alt="" /></p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/high-voltage-switches/qbd-bt-series-bench-top-pockels-cell-drivers-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>QBU-BT-series bench-top Pockels cell Drivers</title>
		<link>http://vigitek.biz/high-voltage-switches/qbu-bt-series-bench-top-pockels-cell-drivers-2/</link>
		<comments>http://vigitek.biz/high-voltage-switches/qbu-bt-series-bench-top-pockels-cell-drivers-2/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 05:12:50 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Pockels Cell Drivers & HV Switches]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=820</guid>
		<description><![CDATA[Description QBU-BT-series consist of five Pockels cell drivers differ with their output voltage range (see also How to order? section) and covering range up to 6.0 kV. Modules allow operations in three different modes (pull down scheme (= normally on),push up scheme (= &#8230; <a href="http://vigitek.biz/high-voltage-switches/qbu-bt-series-bench-top-pockels-cell-drivers-2/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<h2>Description</h2>
<p>QBU-BT-series consist of five Pockels cell drivers differ with their output voltage range (see also <em>How to order</em>? section) and covering range up to 6.0 kV.</p>
<p>Modules allow operations in three different modes (<em>pull down scheme</em> (= normally on),<em>push up scheme</em> (= normally off) and <em>external synchronization mode</em> (= repetition of external low voltage signal)) and therefore suit ideally for the laboratory usage.<br /><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbu-bt-t1.jpg" alt="" /><br />High repetition rates and fast transition times are additional benefits.</p>
<h2>Performance</h2>
<p>For QBU-BT-5020 continuously operated in internal synchronization mode we warrant the performance table as follows:<br /><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbu-bt-t2.jpg" alt="" /></p>
<p>External synchronization mode shows usually a little higher performance.</p>
<p>In the <em>burst-mode</em> (= short time operations) performance is increasing approximately twice and may achieve 100 kHz value at low operating voltages and load capacitance.</p>
<p>High load capacitance decreases the performance.</p>
<h2>Specification</h2>
<p><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbu-bt-t3.jpg" alt="" /></p>
<h2>How to order?</h2>
<p><img src="http://vigitek.biz/wp-content/uploads/2011/10/qbu-bt-t4.jpg" alt="" /></p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/high-voltage-switches/qbu-bt-series-bench-top-pockels-cell-drivers-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pockels Cell Driver</title>
		<link>http://vigitek.biz/uncategorized/pockels-cell-driver/</link>
		<comments>http://vigitek.biz/uncategorized/pockels-cell-driver/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 04:59:06 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=813</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/uncategorized/pockels-cell-driver/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LDD-150, 250, 400 &#8211; Medium power laser diode drivers (CW)</title>
		<link>http://vigitek.biz/cw-laser-diode-drivers/medium-power-laser-diode-drivers-cw/</link>
		<comments>http://vigitek.biz/cw-laser-diode-drivers/medium-power-laser-diode-drivers-cw/#comments</comments>
		<pubDate>Sat, 22 Oct 2011 03:13:42 +0000</pubDate>
		<dc:creator>victor</dc:creator>
				<category><![CDATA[CW Laser Diode Drivers]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=761</guid>
		<description><![CDATA[ Description In this section is represented a series of laser diode drivers for power supply of laser diodes, laser diode lines, and medium power diode lasers. Maximal output power is 150, 250 or 400 W. Various current/voltage ratios are available. Maximal output current &#8230; <a href="http://vigitek.biz/cw-laser-diode-drivers/medium-power-laser-diode-drivers-cw/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<div style="text-align: left;">
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<h2><img src="http://oem-tech.by/miniarrow.gif" alt="" align="center" /> Description</h2>
<p>In this section is represented a series of laser diode drivers for power supply of laser diodes, laser diode lines, and <strong>medium</strong> power diode lasers.</p>
<p>Maximal output power is 150, 250 or 400 W. Various current/voltage ratios are available. Maximal output current up to 100 A. For more information see <a href="http://vigitek.biz/wp-content/uploads/2011/10/selection-table.pdf">selection table</a></p>
<p>Diode driver characteristics meet the latest versions of medical standards requirements: <em>IEC 60601</em> for electrical safety, <em>IEC 61000-3-2</em> for active power factor correction (PFC) and <em>EN 55011 / CISPR 11 Class A</em> safety requirements for EMI and leakage current.</p>
<p>So modules may be used in different kinds of medical devices without any additional filtration and safety measures.</p>
</td>
</tr>
<tr>
<td colspan="2">
<h2><img src="http://oem-tech.by/miniarrow.gif" alt="" align="center" /> Specification</h2>
<table style="width: 100%;" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<th id="caption" colspan="2">Input:</th>
</tr>
<tr>
<th>Voltage</th>
<th>110/230VAC, 50/60Hz or 230VAC, 50/60Hz</th>
</tr>
<tr>
<th>Current</th>
<th>&lt; 3 A</th>
</tr>
<tr>
<th id="caption" colspan="2">Output:</th>
</tr>
<tr>
<th>Maximum power (<em>W<sub>max</sub></em>)</th>
<th>150, 250 or 400W</th>
</tr>
<tr>
<th>Maximum current (<em>I<sub>max</sub></em>)</th>
<th>selectable in range 5 … 75 A (LDD-150) <br />or 10 : 100 A (LDD-250 and LDD-400)</th>
</tr>
<tr>
<th>Maximum voltage (<em>U<sub>max</sub></em>)</th>
<th>is obtained automatically from formula <em>W<sub>max</sub></em> / <em>I<sub>max</sub></em></th>
</tr>
<tr>
<th>Rise/fall time</th>
<th>&lt; 1 ms (10% to 90% full current),<br />&lt; 500 μs on request</th>
</tr>
<tr>
<th>Current regulation accuracy</th>
<th>&lt; 1% of <em>I<sub>max</sub></em></th>
</tr>
<tr>
<th>Current value error</th>
<th>&lt; 1% of <em>I<sub>max</sub></em></th>
</tr>
<tr>
<th>Current overshoot</th>
<th>&lt; 1% of <em>I<sub>max</sub></em></th>
</tr>
<tr>
<th>Efficiency</th>
<th>&gt; 80%</th>
</tr>
<tr>
<th id="caption" colspan="2">Safety:</th>
</tr>
<tr>
<th>PFC value</th>
<th>&gt; 0.98 (active)</th>
</tr>
<tr>
<th>Leakage current</th>
<th>&lt; 150 μA</th>
</tr>
<tr>
<th>Safety approval</th>
<th>IEC60950, IEC60601-1</th>
</tr>
<tr>
<th>Case fault voltage</th>
<th>4000 VAC</th>
</tr>
<tr>
<th>EMC approval</th>
<th>EN55011 (Class A)</th>
</tr>
<tr>
<th id="caption" colspan="2">Interface:</th>
</tr>
<tr>
<th>Connector</th>
<th><em>15 Pin &#8220;D&#8221;-Sub Female</em></th>
</tr>
<tr>
<th>Current program</th>
<th>analog, 0-10 V</th>
</tr>
<tr>
<th>Current monitor</th>
<th>analog, 0-10 V</th>
</tr>
<tr>
<th>Voltage monitor</th>
<th>analog, 0-10 V</th>
</tr>
<tr>
<th id="caption" colspan="2">Environment:</th>
</tr>
<tr>
<th>Operating temperature</th>
<th>0 : +40 °C</th>
</tr>
<tr>
<th>Storage temperature</th>
<th>-20 : +60 °C</th>
</tr>
<tr>
<th>Humidity</th>
<th>90%, non-condensing</th>
</tr>
<tr>
<th id="caption">Size (LxWxH)</th>
<th>250x180x70 mm</th>
</tr>
<tr>
<th id="caption">Weight</th>
<th>1.8 kg</th>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2><img src="http://oem-tech.by/miniarrow.gif" alt="" align="center" /> Options</h2>
<p>We offer diode driver in several modifications with different maximum output currents and voltages.</p>
<p>First of all user should choose maximal output power (150, 250 or 400 W). Then maximal output current in the range of 10 … 100 A should be selected. Maximal output voltage is obtained automatically as <em>W<sub>max</sub></em> / <em>I<sub>max</sub></em>.</p>
</td>
</tr>
</tbody>
</table>
<p><span style="font-size: small;"><span class="Apple-style-span" style="line-height: 24px;"><br /></span></span></p>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/cw-laser-diode-drivers/medium-power-laser-diode-drivers-cw/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>MICRO-series flashlamp pumped OEM laser heads</title>
		<link>http://vigitek.biz/oem-laser-heads/micro-series-flashlamp-pumped-oem-laser-heads/</link>
		<comments>http://vigitek.biz/oem-laser-heads/micro-series-flashlamp-pumped-oem-laser-heads/#comments</comments>
		<pubDate>Fri, 21 Oct 2011 17:49:57 +0000</pubDate>
		<dc:creator>alex</dc:creator>
				<category><![CDATA[OEM Laser Heads]]></category>

		<guid isPermaLink="false">http://vigitek.biz/?p=453</guid>
		<description><![CDATA[Description MICRO-series laser heads were developed in framework of Mul-T-Lase aesthetic device.  Major advantages are as follows: Ultra-compact design Both free-running and q-switching modes of operations Different wavelengths available (1540nm, 755nm, 1064nm, 1079nm, 1340nm, 2940nm; see also description at Mul-T-Lase &#8230; <a href="http://vigitek.biz/oem-laser-heads/micro-series-flashlamp-pumped-oem-laser-heads/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<h2>Description</h2>
<p>MICRO-series laser heads were developed in framework of Mul-T-Lase aesthetic device. </p>
<p>Major advantages are as follows:</p>
<p>Ultra-compact design</p>
<ul>
<li>Both free-running and q-switching modes of operations</li>
<li>Different wavelengths available (1540nm, 755nm, 1064nm, 1079nm, 1340nm, 2940nm; see also description at Mul-T-Lase homepage)</li>
<li>Exterior cover case and beam-shaping optics as an option.</li>
</ul>
<h2>Options</h2>
<p>MICRO-series laser head can be supplied together with the plastic coverage case.<br />Magnetic detachable tips are used to obtain different spot sizes.<br /> Fractional tips for ablative- or non-ablative skin resurfacing are available too.</p>
<p><img src="http://vigitek.biz/wp-content/uploads/2011/10/micro-t1.jpg" alt="" /><img class="alignnone size-full wp-image-952" title="Излучатель_LM4450K (2)-1" src="http://vigitek.biz/wp-content/uploads/2011/10/Излучатель_LM4450K-2-1.jpg" alt="" width="480" height="371" /></p>
]]></content:encoded>
			<wfw:commentRss>http://vigitek.biz/oem-laser-heads/micro-series-flashlamp-pumped-oem-laser-heads/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

